Jeff Wallace
Optimizely
Nov 2, 2012
visibility 7090
star star star star star
(0 votes)

Developers: Before You Build that Alloy 7 Project…

Based on EPiServer 7 and the new Alloy templates

If you have been able to get your hands on EPiServer 7 or experienced any kind of demo you’ll probably be pretty excited about it.  It’s pretty slick!  Since there’s plenty of blogs that tell this story already I won’t re-hash the greatness in this one.  Instead I want to make sure you are aware of a change to the Alloy template project before you build for the first time.

 

The new project includes some post build steps that will copy some of the configs from a new location in the file/project structure over to the root. 

 

image

Post Build Events

 

One of my colleagues explained this process based on some information that was presented at one of the summits this week:


“Every time the project is built, the following is executed by the MSBuild scripts in the [MSBuild] folder:

1. Retrieve default EPiServer configuration files from the "[Configuration]\EPiServer" folder
2. Apply common config transforms from the "[Configuration]\Common" folder
3. Apply build configuration-specific transforms from the "[Configuration]\BUILDCONFIGNAME" folder
(where BUILDCONFIGNAME is the current build configuration name, such as "Debug" or "Release")
4. Overwrite any existing configuration files in the site root

Note: The MSBuild scripts are executed through a post-build event.
Make sure all files in this folder have their Build Action set to "None" to avoid this folder being included when performing a Publish”

 

You’ll also find the above conveniently placed in “_ReadMe.txt” in the Alloy project under the “[Configuration]” folder.

 

image image

[MSBuild] folder and [Configuration] folders

 

You might notice the “Web.config.ReadMe.txt” file in the site root also reads as follows:

“Note that the Web.config file in the root should not be modified directly as it will be overwritten every time the web application is built (because of config transforms).

Configuration changes should be done in the [Configuration] folder.

See the readme file in the [Configuration] folder for detail”

 

Obviously, in general, this is good knowledge to have for Alloy.  Developers who build Add-on modules that update configs, via Nuget or otherwise, may want to account for this in the current project state or if this approach is to be carried forward in other projects.  If developers do not account for this by adding these changes below the “[Configuration]” folder their changes may be overwritten when a build occurs.  Site owner Add-ons should not update the configs but that’s a different story.

 

It appears that the CMO module has this issue since it updates configs such as web.config, episerverframework.config, connectionstrings.config, etc at the site root.  It does not update the files under [Configuration] currently.  What this means to you is that if you install CMO on a standard Alloy 7 site and build your project the CMO configs will be overwritten and CMO will no longer be available in the UI.

 

For the time being you have a couple of obvious choices:

1) Update the configs appropriately under the “[Configuration]” folder to included any necessary changes

2) Remove the post build steps – this is more of a  workaround of the intended build process so not the best long term approach

 

UPDATE: Ted Nyberg has provided an excellent article explaining technical details on the new templates including the config transforms.

 

Now that you are “in the know” get back to enjoying this excellent new release!

Nov 02, 2012

Comments

Nov 3, 2012 11:57 AM

A workaround for installing modules on Alloy is also described here: http://world.episerver.com/Documentation/Items/Installation-Instructions/Installation-Instructions---EPiServer-7/Modules-and-Alloy-Templates-Configuration/

Jeff Wallace
Jeff Wallace Nov 3, 2012 02:36 PM

Great point Sergii. Thanks for adding that link!

Apr 15, 2013 07:25 AM

Still not very sure how to do it before building the Alloy project.

mattias_jonsson_cycom
mattias_jonsson_cycom Apr 23, 2013 01:51 PM

Thanks a lot for helping me fix this problem!

error Please login to comment.
Latest blogs
When MCP and Code-First Both Define a Content Type in Optimizely CMS 13

Most CMS projects define content types in C#. The CMS 13 MCP server adds a second way: an agent calls paas_cms_create_content_type and the type lan...

Adnan Zameer | Nov 25, 2026 |

Exciting New DXP Feature: Read Only SQL access for PaaS

Optimizely has just launched a feature that many of us working with CMS PaaS have been waiting for: self-serve read-only SQL access . For the first...

Scott Reed | Nov 24, 2026

SEO Manager for higher ranking

Which pages are missing an SEO title or meta description? Epicweb SEO Manager helps you find them, review AI suggestions alongside each page, and...

Luc Gosso (MVP) | Nov 24, 2026 |

Headless PaaS CMS 13 Masterclass, Part 2: Architecture overview

How Optimizely CMS 13, Optimizely Graph and a Next.js front end fit together, what headless gains and loses on CMS 13, and the stack this mastercla...

Michał Mitas | Nov 24, 2026 |